Installation of Hybrid Inverter DEYE – Page 3

Applicable for models SUN-5K/6K/8K/10K/12K-SG04LP3-EU

 

6. Mode

Mode 1 Basic
Mode 1 Basic
Mode 2 with generator
Mode 2 With generator
Mode 3 smart load
Mode 3 Smart load
Mode 4 AC Couple
Mode 4 AC Couple

The 1st priority power of the system is always the PV power, then 2nd and 3rd priority power will be the battery bank or grid according to the settings.
The last power backup will be the Generator if it is available.

7. Limitation of Liability

In addition to the product warranty described above, the state and local laws and regulations provide financial compensation for the product’s power connection (including violation of implied terms and warranties). The company hereby declares that the terms and conditions of the product and the policy cannot and can only legally exclude all liability within a limited scope.

Chart 7-1 Fault information

Under the guidance of our company, customers return our products so that our company can provide service of maintenance or replacement of products of the same value. Customers need to pay the necessary freight and other related costs. Any replacement or repair of the product will cover the remaining warranty period of the product. If any part of the product or product is replaced by the company itself during the warranty period, all rights and interests of the replacement product or component belong to the company.
The factory warranty does not include damage due to the following reasons:
– Damage during transportation of equipment;
– Damage caused by incorrect installation or commissioning;
– Damage caused by failure to comply with operation instructions, installation instructions or maintenance instructions;
– Damage caused by attempts to modify, alter or repair products;
– Damage caused by incorrect use or operation;
– Damage caused by insufficient ventilation of equipment;
– Damage caused by failure to comply with applicable safety standards or regulations;
– Damage caused by natural disasters or force majeure (e.g. floods, lightning, overvoltage, storms, fires, etc.)
In addition, normal wear or any other failure will not affect the basic operation of the product.
Any external scratches, stains, or natural mechanical wear does not represent a defect in the product.

8. Datasheets

  1. Three Phase Hybrid Inverter DEYE SUN-5K-SG04LP3-EU 5kVA
  2. Three Phase Hybrid Inverter DEYE SUN-6K-SG04LP3-EU 6kVA
  3. Three Phase Hybrid Inverter DEYE SUN-8K-SG04LP3-EU 8kVA
  4. Three Phase Hybrid Inverter DEYE SUN-10K-SG04LP3-EU 10kVA
  5. Three Phase Hybrid Inverter DEYE SUN-12K-SG04LP3-EU 12kVA

9. Appendix I

Definition of R145 Port Pin for BMS

No. RS485 Pin
1 485_B
2 485_A
3
4 CAN-H
5 CAN-L
6 GND_485
7 485_A
8 485_B
BMS-port

Definition of RJ45 Port Pin for Meter-485

No. Meter-485 Pin
1 METER-485_B
2 METER-485_A
3 COM-GND
4
5
6 COM-GND
7 METER-485_A
8 METER-485_B
Meter-485 Port

Definition of RJ45 Port Pin of “Modbus port” for remote monitoring

No. Modbus port
1 485_B
2 485_A
3 GND_485
4
5
6 GND_485
7 485_A
8 485_B
*Note: for some hardware versions, this port is useless
Modbus port

RS232 port is used to connect the wifi datalogger

No. WIFI/RS232
1  
2 TX
3 RX
4  
5 D-GND
6  
7  
8  
9 12Vdc
WIFI RS232

10. Appendix ll

1. Split Core Current Transformer (CT) dimension: (mm)
2. Secondary output cable length is 4m.

Split Core Current Transformer (CT) dimension (mm)
Split Core CT

 

Similar articles

+380 95 710 0100

contact@solenergy.com.ua

Pay with card

SOL Energy © -